Macintosh se video issue

Validito

Member
Hey,

Trying to revive old Macintosh SE.
Initially, it had one vertical line, solved by resoldering connector points on analog PCB.

Then vertical bars appeared, as you can see vertical bars cross the floppy icon and cursor.

Cleaned and recapped analog board, replaced ue8, and tested the continuity of suspicious traces.

After replacing ue8 with 74hc166 (the old one I think should be 74ls166), still has vertical bars and some flicker on the background.
The interesting thing is floppy icon and cursor are not affected by flicker, at least look different.

Then, by testing traces, accidentally found that when heating PAL IC`s UG7 or UG8, I get a clean picture, and it starts flickering after cooling down.

Tested again with old ue8 74ls166 - heating UG7 or UG8 does not affect the picture at all, stable vertical bars, no flicker.

In both cases, it has a startup sound.

I think UG7 or UG8 cannot be bad, as heating them with old ue8 does not affect the picture at all.

So now I am thinking, can it be 74hc166 is not suitable, and I should find 74ls166 because somehow the signal for UG7 or UG8 is incorrect with it, and after heating UG7 or UG8 somewhere, resistance increases, and it solves the problem temporarily?

Maybe any other ideas?
 

Attachments

  • 1 - with old ue8 74ls166.JPG
    1 - with old ue8 74ls166.JPG
    277.7 KB · Views: 7
  • 2 - with new ue8 74hc166.JPG
    2 - with new ue8 74hc166.JPG
    223.5 KB · Views: 6
  • 3 - with new ue8 74hc166.png
    3 - with new ue8 74hc166.png
    682.8 KB · Views: 7
  • 4 - after heating ug7 or ug6 with new ue8.png
    4 - after heating ug7 or ug6 with new ue8.png
    623.7 KB · Views: 7
Last edited:

bibilit

Well-known member
I had troubles using the HC instead of the LS at some point, so can be your issue here.

No bad solder joint or bad trace solved by heating the area ?
 

Validito

Member
I had troubles using the HC instead of the LS at some point, so can be your issue here.

No bad solder joint or bad trace solved by heating the area ?
Not that I have found any, I have reflowed UG7 or UG8 ( ones that I heat to make it work ), but no change there.
Probably will try to source 74ls166 on ebay or something, locally only hc`s are available.
 

Validito

Member
Not that I have found any, I have reflowed UG7 or UG8 ( ones that I heat to make it work ), but no change there.
Probably will try to source 74ls166 on ebay or something, locally only hc`s are available.

After some searching (https://electronicsclub.info/74series.htm):
The 74LS (Low-power Schottky) family (like the original) uses TTL (Transistor-Transistor Logic) circuitry which is fast but requires more power than later families.

The 74HC family has High-speed CMOS circuitry, combining the speed of TTL with the very low power consumption of the 4000 series. They are CMOS ICs with the same pin arrangements as the older 74LS family. Note that 74HC inputs cannot be reliably driven by 74LS outputs because the voltage ranges used for logic 0 are not quite compatible, use 74HCT instead.

The 74HCT family is a special version of 74HC with 74LS TTL-compatible inputs so 74HCT can be safely mixed with 74LS in the same system. In fact 74HCT can be used as low-power direct replacements for the older 74LS ICs in most circuits.

So, ordered 74HCT166, will see how it goes :)
 

Validito

Member
Just answering my own question, just changed and tested with 74HCT166 and picture is clear perferct! :)
So, the proper replacement for 74ls166 is 74HCT166 and not 74HC166!
 