• Updated 2023-07-12: Hello, Guest! Welcome back, and be sure to check out this follow-up post about our outage a week or so ago.

Powerbook 2400c inverter

Powerbook27364

Well-known member
I’ll take a look at those options tonight and hopefully I can figure out where the problem is.

I don’t know much about inverters/ccfl bulbs but do they need anything special to power the bulbs? Would it be possible to just hook the required voltage up to the bulb and run it like that without an inverter?

I really don’t want to buy another 2400 for a display and inverter but if I can’t get either that might be the last option.
 

jlindsay26

Well-known member
I'll be honest I'm not an expert either. I just remembered years ago replacing the CCFL bulb on a 2400c with a bulb for Frys electronics and that worked, so I tried that on this one and it didn't work. After that I bought a tester on Amazon using that the backlight works fine so I put up my post to see if anyone knows a bit more about the inverter in the 2400c.
 

Powerbook27364

Well-known member
Fair enough. Hopefully this will at least make some attention towards it since these are rare enough already and failure of the inverter seems common. I’ll ask a friend who deals with these computers to see if he knows anything about the inverters
 

Powerbook27364

Well-known member
Do you have any working inverters you could try to find the voltage readings compare to these damaged or dead inverters? Might give some insight into the problem.
 

Powerbook27364

Well-known member
After several months and a second display and second dead inverter I finally fixed it. Both inverters had a blown F1 fuse. After bridging the fuse (I am ordering a replacement), the inverter is working perfectly again. Maybe that is your issue as well.
 

jlindsay26

Well-known member
After several months and a second display and second dead inverter I finally fixed it. Both inverters had a blown F1 fuse. After bridging the fuse (I am ordering a replacement), the inverter is working perfectly again. Maybe that is your issue as well.
I’ll give bridging F1 a try thanks
 

MacUp72

Well-known member
After several months and a second display and second dead inverter I finally fixed it. Both inverters had a blown F1 fuse. After bridging the fuse (I am ordering a replacement), the inverter is working perfectly again. Maybe that is your issue as well.
Maybe it should be important to know what caused that fuse blow
 

finkmac

NORTHERN TELECOM
Maybe it should be important to know what caused that fuse blow

it would be nice to know, yeah. but it could also just be a fuse that went bad.
honestly i wonder what percentage of failed fuse 2400c inverters are from japan. the humidity there might be a factor in failing fuses.
actually now that i think of it, i wonder how many failed fuses are on displays with vinegar syndrome 🤔
 

Powerbook27364

Well-known member
Maybe it should be important to know what caused that fuse blow
I looked for any unusual signs of damage or overuse, but didn't find anything indicative of a problem. Just the fuse seemed to be bad, and everything else looked to be in good shape.

it would be nice to know, yeah. but it could also just be a fuse that went bad.
honestly i wonder what percentage of failed fuse 2400c inverters are from japan. the humidity there might be a factor in failing fuses.
actually now that i think of it, i wonder how many failed fuses are on displays with vinegar syndrome 🤔
Well, both of my displays had vinegar syndrome, one much more so than the other. Both also came from Japan.
 

finkmac

NORTHERN TELECOM
both of my badfuse inverters are from (japanese) vinegar syndrome 2400s as well.
the one good polarizer display unit didn't have the bad fuse.
 
Top