W?here to meter other voltages Color Classic analogue board post recap

captaineos

Well-known member
Hi everyone
Grateful to have 68KMLA going strong. Jeremy from Australia
Am doing a comprehensive service of my colour classics, re-capping the power supplies and enjoying it.
I have put together my own cap list, resistor upgrades and taken notes.

One thing I can't work out is where I can safely meter voltages from - specifically high voltage. Not anode cap.

Situation is colour classic recapped -> now turning on -> G2 was too high so nipped the pot back and now have perfect black levels / strong contrast.
However
Vertical bounce / UNSTABLE image (slight!)
Enough to make your eyes sore but slight enough to make you think twice

I explored an idea of mine that maybe a resistor or component is getting too hot but it's there from cold boot / an industrial blower pushing cool air over board and raster the same.

Have put a fair amount of time in reflowing / desoldering / resoldering / cleanup / ensuring some traces patched over for good continuity.

I assume I have an unstable high voltage or low high voltage at some point but can't find any reference to something like "test point 8 should be 200v".

Halp appreciated. From the molex hard drive connector I have verbatim +5.0v and +12.0v present.
 

Attachments

  • 2023-01-02_12-54-54.jpg
    2023-01-02_12-54-54.jpg
    1.5 MB · Views: 5
Last edited:
Top